Skip to main content

Table 3 \(\Delta\)TO and \(\Delta\)HS of our main algorithm for each cohort

From: Automatic gait events detection with inertial measurement units: healthy subjects and moderate to severe impaired patients

 

CS (n = 16819)

MS (n = 6067)

EVF (n = 8951)

F1

100

99.4

96.3

Recall (%)

100

99.7

96.7

Precision (%)

100

99.2

96.0

TO events

8410

3002

4381

Median \(\Delta\)TO [IQR]

8 [3–15]

23 [10–50]

27 [15–48]

HS events

8409

3065

4570

Median \(\Delta\)HS [IQR]

7 [3–12]

15 [7–30]

25 [10–50]

  1. All the results are given in milliseconds
  2. CS control subjects, MS multiple sclerosis patients, EVF equino varus foot patients, TO Toe-Off, HS Heel-Strike